- Assay results for 67 holes have been received to date (representing approximately 16,680 meters or 71% of the length drilled), of which 25 holes (representing 30% of the length drilled) were announced on
August 6 andOctober 26, 2020 :- Assay results continue to demonstrate higher drilled grade-thickness than predicted by previous modelling
- Data collected has resulted in an improved understanding of the controls on mineralization
- Remaining assay results from the 2020 program are expected in the first quarter of 2021
- Additional confirmation and extension drilling planned for 2021
- No Covid-19 cases and zero Lost Time Injuries on site in 2020
- Ongoing community support, providing timely responses for needs arising from the Covid-19 pandemic
Objectives of the 2020 Drill Program and Results to Date
The primary objective of the 2020 drill program, the largest such campaign at Donlin Gold since 2008, has been to validate and increase the confidence in recent geologic modeling concepts.
Results to date, in both the ACMA and Lewis deposit areas, continue to exceed modeled grade-thickness, with higher grades observed over narrower intervals, particularly in sedimentary rocks. Final assay results for the 2020 drill program are expected to be reported in the first quarter of 2021.
Additional confirmation and extension drilling are planned in 2021 focusing on mineralization continuity, structural control, resource model upgrades, and geotechnical data collection. The program specifics will be finalized once all assay results have been received and integrated into an interim model update.
- Five of the top intervals received since the
October 26, 2020 media release include:- DC20-1937 intersected 103.88 m grading 6.1 g/t gold, starting at 390.19 m drilled depth, including a sub interval of 22.15 m grading 12.5 g/t, starting at 459.17 m drilled depth;
- DC20-1903 intersected 8.14 m grading 45.3 g/t gold, starting at 99.39 m drilled depth, including a sub interval of 6.84 m grading 52.1 g/t gold, starting at 99.39 m drilled depth;
- DC20-1912 intersected 37.30 m grading 7.0 g/t gold, starting at 249.70 m drilled depth, including a sub interval of 3.30 m grading 24.5 g/t gold, starting at 251.70 m drilled depth;
- DC20-1930 intersected 39.15 m grading 4.3 g/t gold, starting at 148.85 m drilled depth, including a sub interval of 5.60 m grading 12.5 g/t gold, starting at 182.40 m drilled depth; and
- DC20-1895 intersected 23.80 m grading 6.5 g/t gold, starting at 218.28 m drilled depth, including a sub interval of 7.12 m grading 12.7 g/t gold, starting at 220.28 m drilled depth.
- Drill hole collar locations and five of the top intervals since
October 26, 2020 are shown in Figure 1 - Drill hole orientations and depths and significant intervals are shown in Tables 1 and 2, respectively, in the Appendix at the end of this release
Statements by the Owners
With more than 70% of drill assays now reported, the results of the 2020 drill program continue to advance Donlin Gold up the value chain.
“Assay results received to date are encouraging and support the drill program to better understand the Donlin Gold orebody and de-risk the project development. The ongoing modelling work and planned 2021 follow-up drilling program could further enhance the project parameters,” said
Covid-19 Response & Community Engagement Update
In 2020, 80% of Donlin Gold direct hires for the drill program were Alaska Natives. Extensive communication and the application of health and safety protocols resulted in zero Covid-19 cases on site during the year. There were also no lost-time injuries; a testament to the team’s focus on operating safely and effectively. Enhanced Covid-19 health protocols will remain in place at Donlin Gold, with the objective of protecting the health of Donlin Gold’s employees, contractors, along with their families and home communities.
Donlin Gold has worked with its Alaska Native partners Calista, TKC and other key representatives of the communities in the region, responding to needs arising from the Covid-19 pandemic, as well as in other areas such as environmental management, training and education, and cultural initiatives in the Yukon-Kuskokwim region as featured below:
- Covid-19 – Established a partnership with
Bethel Community Services Foundation to support theY-K Resiliency Fund and Covenant House Alaska for homeless and at-risk youth services in Bethel. Supplies were provided to 766 families and meals served to 3,700 participants in the Elders and Youth program. - Environmental - Worked with TKC, the State of
Alaska andAlaska Native Tribal Health Consortium in an initiative to upgrade and improve health & safety standards of water and sewer services in Middle Kuskokwim area communities. - Training & Education – Hosted two virtual Alaska Resource Education camps for Y-K and Doyon students, and Donlin Gold Scholarships were awarded to students selected by Calista and TKC to improve access to education in the region. Calista has awarded a total of 225 scholarships, with 158 students attending schools in
Alaska and the balance having gone to schools out of state, with more than 10 villages in the Y-K region represented. - Cultural Initiatives – Strengthened sponsorship of the
First Alaskans Institute at the Elders & Youth 2020 statewide conference, theAlaska Federation of Natives (AFN) annual convention, and provided distanced activities and programs for youth and Elders.
As part of Donlin Gold’s ongoing community engagement efforts, Friendship Agreements were approved and signed by five communities (
Donlin Gold is a committed partner to the Alaska Native Communities both surrounding the project and within the State as a whole. This commitment underpins our approach and is also reflected in the way in which the asset itself is structured. An important factor that distinguishes Donlin Gold from most other mining assets in
About Donlin Gold
Donlin Gold is located in
FIGURE 1 Drill Hole Collar Locations
A photo accompanying this announcement is available at https://www.globenewswire.com/NewsRoom/AttachmentNg/29faa507-44a1-4ead-bf57-0d534d493951
Depicted grid system is based on NAD83 UTM zone 4N coordinates.
The owners provided previous updates on assay results in the
QA/QC Procedures
The QA/QC procedures for the 2020 Donlin Gold drill program and sampling protocol were developed and managed by
Downhole directional surveys were completed on all reported completed holes by both Boart Longyear drill operators and on 96% of reported completed holes by
Each of ALS Limited, Boart Longyear,
Scientific and Technical Information
Certain scientific and technical information contained herein with respect to the Donlin Gold project is derived from the “Donlin Creek Gold Project Alaska, USA NI 43-101 Technical Report on Second Updated Feasibility Study” prepared by AMEC with an effective date of
Clifford Krall, P.E., who is the Mine Engineering Manager for NOVAGOLD and a “qualified person” under NI 43101, has approved and verified the scientific and technical information related to the 2020 Donlin Gold drill program contained in this media release. To verify the information related to the drilling program, he has visited the project site twice during the 2020 field season; discussed and observed logging, sampling, and sample shipping processes with responsible site staff; discussed and reviewed assay and QA/QC results with responsible personnel; and reviewed supporting documentation, including drill hole location and orientation and significant assay interval calculations.
Barrick Contacts:
Investor and Media Relations
+44 20 7557 7738
Email: barrick@dpapr.com
COO,
Tel: +1 416-307-5157
www.barrick.com
NOVAGOLD Contacts:
Vice President, Corporate Communications
Manager, Investor Relations
Tel: +1 604-669-6227 or 1-866-669-6227
www.novagold.com
Cautionary Note Regarding Forward-Looking Statements
This media release includes certain “forward-looking information” and “forward-looking statements” (collectively “forward-looking statements”) within the meaning of applicable securities legislation, including the United States Private Securities Litigation Reform Act of 1995. Forward-looking statements are frequently, but not always, identified by words such as “expects”, “anticipates”, “believes”, “intends”, “estimates”, “potential”, “possible”, and similar expressions, or statements that events, conditions, or results “will”, “may”, “could”, “would” or “should” occur or be achieved. Forward-looking statements are necessarily based on several opinions, estimates and assumptions that management of Barrick and NOVAGOLD considered appropriate and reasonable as of the date such statements are made, are subject to known and unknown risks, uncertainties, assumptions and other factors that may cause the actual results, activity, performance or achievements to be materially different from those expressed or implied by such forward-looking statements. All statements, other than statements of historical fact, included herein are forward-looking statements. These forward-looking statements include statements regarding anticipated benefits from the 2020 drill program including an improved geological model for Donlin Gold; ongoing support provided to key stakeholders including
Important factors that could cause actual results to differ materially from expectations include the need to obtain additional permits and governmental approvals; the timing and likelihood of permits including the right-of-way lease offer for the project’s buried natural gas pipeline; the need for additional financing to explore and develop properties and availability of financing in the debt and capital markets; the outbreak of the coronavirus global pandemic (Covid-19); uncertainties involved in the interpretation of drill results and geological tests and the estimation of reserves and resources; changes in mineral production performance, exploitation and exploration successes; changes in national and local government legislation, taxation, controls or regulations and/or changes in the administration of laws, policies and practices, expropriation or nationalization of property and political or economic developments in
Cautionary Note to
NOVAGOLD cautions that this media release has been prepared in accordance with the requirements of the securities laws in effect in
On
APPENDIX
TABLE 1
Drill Hole Orientations* and Depths
Hole | Azimuth (°) | Inclination (°) | Depth (m) |
DC20-1865 | 237 | 79 | 227.0 |
DC20-1866 | 45 | 67 | 302.7 |
DC20-1867 | 28 | 73 | 217.5 |
DC20-1868 | 358 | 67 | 247.2 |
DC20-1869 | 330 | 72 | 175.9 |
DC20-1870 | 307 | 71 | 249.9 |
DC20-1871 | 303 | 63 | 458.4 |
DC20-1872 | 312 | 53 | 632.8 |
DC20-1873 | 250 | 49 | 274.9 |
DC20-1874 | 300 | 76 | 253.0 |
DC20-1875 | 304 | 53 | 218.5 |
DC20-1876 | 288 | 69 | 235.0 |
DC20-1877 | 303 | 73 | 249.9 |
DC20-1878 | 304 | 55 | 459.9 |
DC20-1879 | 302 | 58 | 231.0 |
DC20-1880 | 300 | 71 | 249.9 |
DC20-1881 | 301 | 52 | 256.0 |
DC20-1882 | 327 | 56 | 524.9 |
DC20-1883 | 308 | 54 | 266.4 |
DC20-1884 | 306 | 72 | 251.8 |
DC20-1885 | 278 | 63 | 296.6 |
DC20-1886 | 304 | 56 | 255.4 |
DC20-1887 | 305 | 60 | 255.4 |
DC20-1888 | 312 | 72 | 266.5 |
DC20-1889 | 328 | 56 | 406.6 |
DC20-1890 | abandoned before completion, re-drilled as 1891 | ||
DC20-1891 | 331 | 55 | 377.3 |
DC20-1892 | 184 | 63 | 300.2 |
DC20-1893 | 312 | 75 | 260.9 |
DC20-1894 | 230 | 67 | 620.6 |
DC20-1895 | 329 | 53 | 362.1 |
DC20-1896 | abandoned before completion, re-drilled as 1898 | ||
DC20-1897 | 325 | 59 | 335.0 |
DC20-1898 | 302 | 77 | 250.9 |
DC20-1899 | 358 | 63 | 201.0 |
DC20-1900 | 302 | 71 | 235.0 |
DC20-1901 | 306 | 65 | 464.8 |
DC20-1902 | 287 | 61 | 176.2 |
DC20-1903 | 259 | 64 | 150.7 |
DC20-1904 | 0 | 69 | 200.0 |
DC20-1905 | 290 | 58 | 212.5 |
DC20-1906 | 181 | 77 | 347.8 |
DC20-1907 | 305 | 63 | 431.6 |
DC20-1908 | 305 | 60 | 351.4 |
DC20-1909 | 5 | 75 | 239.3 |
DC20-1910 | 288 | 51 | 235.0 |
DC20-1911 | 1 | 78 | 150.3 |
DC20-1912 | 302 | 65 | 474.3 |
DC20-1913 | 296 | 63 | 224.9 |
DC20-1914 | 290 | 66 | 200.3 |
DC20-1915 | 309 | 67 | 325.5 |
DC20-1916 | 295 | 69 | 218.2 |
DC20-1917 | 50 | 65 | 175.3 |
DC20-1918 | 305 | 67 | 252.4 |
DC20-1919 | 272 | 57 | 249.0 |
DC20-1920 | 313 | 49 | 253.3 |
DC20-1921 | 235 | 54 | 607.2 |
DC20-1922 | 318 | 68 | 254.5 |
DC20-1923 | 301 | 69 | 211.5 |
DC20-1924 | 297 | 63 | 228.0 |
DC20-1925 | 290 | 54 | 210.0 |
DC20-1926 | 291 | 70 | 150.3 |
DC20-1927 | 296 | 68 | 299.9 |
DC20-1928 | 299 | 65 | 226.2 |
DC20-1929 | 289 | 58 | 214.9 |
DC20-1930 | 208 | 64 | 233.2 |
DC20-1931 | 295 | 65 | 152.7 |
DC20-1932 | 289 | 56 | 175.3 |
DC20-1933 | 295 | 59 | 200.0 |
DC20-1934 | 289 | 54 | 250.2 |
DC20-1935 | 282 | 69 | 150.0 |
DC20-1936 | 1 | 68 | 231.0 |
DC20-1937 | 256 | 68 | 531.9 |
DC20-1938 | 307 | 67 | 150.0 |
DC20-1939 | 171 | 79 | 151.8 |
DC20-1940 | 292 | 62 | 200.0 |
DC20-1941 | 104 | 85 | 175.0 |
DC20-1942 | 273 | 60 | 175.3 |
DC20-1943 | 326 | 78 | 215.5 |
DC20-1944 | 279 | 61 | 320.0 |
DC20-1945 | 305 | 77 | 283.8 |
DC20-1946 | 17 | 52 | 263.0 |
DC20-1947 | 304 | 76 | 240.2 |
DC20-1948 | 306 | 59 | 305.1 |
DC20-1949 | 326 | 56 | 303.6 |
DC20-1950 | 325 | 59 | 334.1 |
DC20-1951 | 6 | 73 | 178.8 |
* Note that azimuth and inclination values vary as each hole progresses. The stated values are hole averages, rounded to the nearest degree.
TABLE 2
2020 Donlin Gold Significant Assay Intervals
Hole ID | Area | From (Meters) | To (Meters) | Length (Meters) | ||
DC20-1865 | ACMA | 136.75 | 149.16 | 12.41 | 4.91 | Reported 8/6 |
DC20-1865 | 155.50 | 174.21 | 18.71 | 2.03 | Reported 8/6 | |
DC20-1865 | 200.22 | 213.57 | 13.35 | 2.97 | Reported 8/6 | |
DC20-1865 | TOTAL | 44.47 | 3.12 | |||
DC20-1866 | ACMA | 14.00 | 17.82 | 3.82 | 3.48 | Reported 8/6 |
DC20-1866 | 35.39 | 81.30 | 45.91 | 5.03 | Reported 8/6 | |
including | 63.35 | 75.30 | 11.95 | 10.44 | Reported 8/6 | |
DC20-1866 | 98.25 | 103.42 | 5.17 | 7.01 | Reported 8/6 | |
DC20-1866 | 108.30 | 131.66 | 23.36 | 4.15 | Reported 8/6 | |
DC20-1866 | 208.44 | 221.61 | 13.17 | 4.69 | Reported 8/6 | |
DC20-1866 | 226.53 | 256.81 | 30.28 | 4.20 | Reported 8/6 | |
DC20-1866 | 266.00 | 276.76 | 10.76 | 4.72 | Reported 8/6 | |
DC20-1866 | 281.33 | 285.57 | 4.24 | 1.83 | Reported 8/6 | |
DC20-1866 | 291.00 | 296.86 | 5.86 | 5.61 | Reported 8/6 | |
DC20-1866 | TOTAL | 142.57 | 4.61 | |||
DC20-1867 | ACMA | 23.20 | 28.04 | 4.84 | 7.37 | Reported 8/6 |
DC20-1867 | 66.14 | 70.74 | 4.60 | 5.90 | Reported 8/6 | |
DC20-1867 | 92.68 | 104.00 | 11.32 | 6.17 | Reported 8/6 | |
DC20-1867 | TOTAL | 20.76 | 6.39 | |||
DC20-1868 | ACMA | 115.51 | 125.74 | 10.23 | 4.13 | Reported 8/6 |
DC20-1868 | 243.48 | 247.19 | 3.71 | 1.92 | Reported 8/6 | |
DC20-1868 | TOTAL | 13.94 | 3.54 | |||
DC20-1869 | ACMA | 10.80 | 16.15 | 5.35 | 3.22 | Reported 8/6 |
DC20-1869 | 33.30 | 43.30 | 10.00 | 2.68 | Reported 8/6 | |
DC20-1869 | 49.30 | 58.83 | 9.53 | 3.86 | Reported 8/6 | |
DC20-1869 | 128.19 | 137.60 | 9.41 | 3.08 | Reported 8/6 | |
DC20-1869 | TOTAL | 34.29 | 3.20 | |||
DC20-1870 | ACMA | 156.66 | 164.60 | 7.94 | 4.24 | Reported 8/6 |
DC20-1870 | 173.10 | 180.80 | 7.70 | 7.53 | Reported 8/6 | |
DC20-1870 | TOTAL | 15.64 | 5.86 | |||
DC20-1871 | ACMA | 12.80 | 20.80 | 8.00 | 4.01 | Reported 8/6 |
DC20-1871 | 30.35 | 72.26 | 41.91 | 11.61 | Reported 8/6 | |
including | 38.24 | 42.24 | 4.00 | 17.00 | Reported 8/6 | |
including | 55.78 | 62.26 | 6.48 | 38.77 | Reported 8/6 | |
DC20-1871 | 341.67 | 347.44 | 5.77 | 1.00 | Reported 8/6 | |
DC20-1871 | 425.97 | 435.71 | 9.74 | 1.60 | Reported 10/26 | |
DC20-1871 | TOTAL | 65.42 | 8.25 | |||
DC20-1872 | Lewis | 47.30 | 73.46 | 26.16 | 3.40 | Reported 10/26 |
DC20-1872 | 82.80 | 86.60 | 3.80 | 4.74 | Reported 10/26 | |
DC20-1872 | 163.82 | 167.70 | 3.88 | 4.39 | Reported 8/6 | |
DC20-1872 | 290.62 | 294.58 | 3.96 | 3.17 | Reported 8/6 | |
DC20-1872 | 544.34 | 555.00 | 10.66 | 1.80 | Reported 10/26 | |
DC20-1872 | 603.23 | 609.23 | 6.00 | 2.33 | Reported 10/26 | |
DC20-1872 | TOTAL | 54.46 | 3.11 | |||
DC20-1873 | Lewis | 42.90 | 53.74 | 10.84 | 4.36 | Reported 8/6 |
DC20-1873 | 60.88 | 68.54 | 7.66 | 18.40 | Reported 8/6 | |
including | 63.16 | 68.54 | 5.38 | 25.26 | Reported 8/6 | |
DC20-1873 | TOTAL | 18.50 | 10.17 | |||
DC20-1874 | ACMA | 159.39 | 169.59 | 10.20 | 7.24 | Reported 10/26 |
DC20-1874 | 174.65 | 177.97 | 3.32 | 3.51 | Reported 10/26 | |
DC20-1874 | 236.83 | 239.88 | 3.05 | 5.52 | Reported 10/26 | |
DC20-1874 | TOTAL | 16.57 | 6.18 | |||
DC20-1875 | Lewis | 18.75 | 22.64 | 3.89 | 1.50 | Reported 10/26 |
DC20-1875 | 43.17 | 47.09 | 3.92 | 1.95 | Reported 10/26 | |
DC20-1875 | 100.06 | 105.68 | 5.62 | 6.09 | Reported 10/26 | |
DC20-1875 | TOTAL | 13.43 | 3.55 | |||
DC20-1876 | ACMA | 5.62 | 18.35 | 12.73 | 5.35 | Reported 10/26 |
DC20-1876 | TOTAL | 12.73 | 5.35 | |||
DC20-1877 | ACMA | 123.48 | 127.65 | 4.17 | 80.58 | Reported 10/26 |
including | 124.50 | 127.65 | 3.15 | 106.24 | Reported 10/26 | |
DC20-1877 | TOTAL | 4.17 | 80.58 | |||
DC20-1878 | Lewis | 27.47 | 34.05 | 6.58 | 2.83 | Reported 10/26 |
DC20-1878 | 48.86 | 68.63 | 19.77 | 11.34 | Reported 10/26 | |
including | 54.86 | 61.86 | 7.00 | 25.24 | Reported 10/26 | |
DC20-1878 | 74.63 | 79.74 | 5.11 | 15.79 | Reported 10/26 | |
including | 74.63 | 77.74 | 3.11 | 21.10 | Reported 10/26 | |
DC20-1878 | 96.92 | 105.70 | 8.78 | 1.23 | Reported 10/26 | |
DC20-1878 | 120.32 | 124.31 | 3.99 | 1.83 | Reported 10/26 | |
DC20-1878 | 132.14 | 135.94 | 3.80 | 1.21 | Reported 10/26 | |
DC20-1878 | 140.90 | 154.70 | 13.80 | 3.10 | Reported 10/26 | |
DC20-1878 | 175.34 | 186.70 | 11.36 | 2.00 | Reported 10/26 | |
DC20-1878 | 198.40 | 240.70 | 42.30 | 2.03 | Reported 10/26 | |
DC20-1878 | 244.75 | 247.92 | 3.17 | 4.27 | Reported 10/26 | |
DC20-1878 | TOTAL | 118.66 | 4.31 | |||
DC20-1879 | Lewis | 62.30 | 68.44 | 6.14 | 1.85 | Reported 10/26 |
DC20-1879 | 118.57 | 149.20 | 30.63 | 2.40 | Reported 10/26 | |
DC20-1879 | TOTAL | 36.77 | 2.31 | |||
DC20-1880 | ACMA | 40.70 | 44.80 | 4.10 | 10.67 | Reported 10/26 |
DC20-1880 | 136.30 | 139.80 | 3.50 | 10.23 | Reported 10/26 | |
DC20-1880 | TOTAL | 7.60 | 10.47 | |||
DC20-1881 | ACMA | 50.75 | 55.25 | 4.50 | 3.03 | Reported 10/26 |
DC20-1881 | TOTAL | 4.50 | 3.03 | |||
DC20-1882 | ACMA | 5.00 | 9.00 | 4.00 | 4.52 | Reported 10/26 |
DC20-1882 | 15.00 | 21.00 | 6.00 | 6.54 | Reported 10/26 | |
DC20-1882 | 27.00 | 43.00 | 16.00 | 2.81 | Reported 10/26 | |
DC20-1882 | 67.00 | 71.00 | 4.00 | 1.51 | Reported 10/26 | |
DC20-1882 | 113.11 | 121.27 | 8.16 | 4.28 | Reported 10/26 | |
DC20-1882 | 160.18 | 167.55 | 7.37 | 2.11 | Reported 10/26 | |
DC20-1882 | 200.80 | 219.63 | 18.83 | 1.75 | Reported 10/26 | |
DC20-1882 | 233.97 | 245.15 | 11.18 | 4.73 | Reported 10/26 | |
DC20-1882 | 251.03 | 255.03 | 4.00 | 3.90 | Reported 10/26 | |
DC20-1882 | 302.03 | 328.53 | 26.50 | 2.24 | Reported 10/26 | |
DC20-1882 | 336.49 | 349.54 | 13.05 | 2.32 | Reported 10/26 | |
DC20-1882 | 392.24 | 402.03 | 9.79 | 2.99 | Reported 10/26 | |
DC20-1882 | TOTAL | 128.88 | 2.94 | |||
DC20-1883 | Lewis | 49.38 | 62.00 | 12.62 | 2.19 | Reported 10/26 |
DC20-1883 | 137.16 | 157.45 | 20.29 | 1.21 | Reported 10/26 | |
DC20-1883 | 172.70 | 178.97 | 6.27 | 2.54 | Reported 10/26 | |
DC20-1883 | 214.50 | 222.50 | 8.00 | 2.58 | Reported 10/26 | |
DC20-1883 | 230.00 | 234.00 | 4.00 | 9.12 | Reported 10/26 | |
DC20-1883 | 258.50 | 264.50 | 6.00 | 15.45 | Reported 10/26 | |
DC20-1883 | TOTAL | 57.18 | 3.81 | |||
DC20-1884 | ACMA | 142.50 | 152.25 | 9.75 | 5.07 | Reported 10/26 |
DC20-1884 | 163.25 | 167.10 | 3.85 | 2.17 | Reported 10/26 | |
DC20-1884 | TOTAL | 13.60 | 4.25 | |||
DC20-1885 | ACMA | 268.96 | 274.75 | 5.79 | 12.96 | Reported 10/26 |
including | 268.96 | 272.87 | 3.91 | 16.11 | Reported 10/26 | |
DC20-1885 | TOTAL | 5.79 | 12.96 | |||
DC20-1886 | Lewis | 43.76 | 49.67 | 5.91 | 2.17 | Reported 10/26 |
DC20-1886 | 125.88 | 139.80 | 13.92 | 3.47 | Reported 10/26 | |
DC20-1886 | 147.00 | 151.00 | 4.00 | 3.95 | Reported 10/26 | |
DC20-1886 | 158.78 | 180.90 | 22.12 | 4.65 | Reported 10/26 | |
including | 172.90 | 176.90 | 4.00 | 12.30 | Reported 10/26 | |
DC20-1886 | 196.80 | 212.20 | 15.40 | 3.37 | Reported 10/26 | |
DC20-1886 | 218.20 | 252.08 | 33.88 | 6.52 | Reported 10/26 | |
including | 224.20 | 232.14 | 7.94 | 11.27 | Reported 10/26 | |
DC20-1886 | TOTAL | 95.23 | 4.75 | |||
DC20-1887 | Lewis | 5.10 | 10.50 | 5.40 | 1.78 | Reported 10/26 |
DC20-1887 | 132.00 | 145.50 | 13.50 | 4.32 | Reported 10/26 | |
including | 134.00 | 138.00 | 4.00 | 10.02 | Reported 10/26 | |
DC20-1887 | 150.45 | 160.00 | 9.55 | 4.65 | Reported 10/26 | |
DC20-1887 | 177.38 | 185.00 | 7.62 | 1.65 | Reported 10/26 | |
DC20-1887 | 212.50 | 218.50 | 6.00 | 1.73 | Reported 10/26 | |
DC20-1887 | TOTAL | 42.07 | 3.22 | |||
DC20-1888 | ACMA | 178.58 | 185.51 | 6.93 | 43.12 | Reported 10/26 |
including | 180.26 | 183.51 | 3.25 | 90.49 | Reported 10/26 | |
DC20-1888 | 191.45 | 203.33 | 11.88 | 1.77 | Reported 10/26 | |
DC20-1888 | TOTAL | 18.81 | 17.00 | |||
DC20-1889 | ACMA | 33.00 | 43.00 | 10.00 | 5.95 | |
including | 35.00 | 39.00 | 4.00 | 11.15 | ||
DC20-1889 | 56.00 | 60.00 | 4.00 | 1.38 | ||
DC20-1889 | 115.00 | 120.00 | 5.00 | 24.27 | ||
including | 115.50 | 118.50 | 3.00 | 32.77 | ||
DC20-1889 | 176.00 | 188.00 | 12.00 | 2.77 | ||
DC20-1889 | 205.50 | 218.50 | 13.00 | 2.68 | ||
DC20-1889 | 281.00 | 306.20 | 25.20 | 2.13 | ||
DC20-1889 | 348.00 | 353.00 | 5.00 | 7.62 | ||
DC20-1889 | TOTAL | 74.20 | 4.67 | |||
DC20-1891 | ACMA | 8.08 | 15.39 | 7.31 | 1.65 | Reported 10/26 |
DC20-1891 | 52.99 | 76.37 | 23.38 | 2.58 | Reported 10/26 | |
DC20-1891 | 107.69 | 121.70 | 14.01 | 2.20 | Reported 10/26 | |
DC20-1891 | 212.43 | 222.39 | 9.96 | 1.66 | ||
DC20-1891 | 228.35 | 248.63 | 20.28 | 3.32 | ||
DC20-1891 | 262.48 | 291.66 | 29.18 | 3.10 | ||
DC20-1891 | 331.37 | 335.37 | 4.00 | 2.33 | ||
DC20-1891 | TOTAL | 108.12 | 2.65 | |||
DC20-1892 | ACMA | 52.51 | 74.19 | 21.68 | 2.39 | |
DC20-1892 | 92.16 | 95.87 | 3.71 | 4.18 | ||
DC20-1892 | 148.00 | 156.00 | 8.00 | 4.12 | ||
DC20-1892 | 184.96 | 188.48 | 3.52 | 1.04 | ||
DC20-1892 | 247.50 | 257.46 | 9.96 | 1.75 | ||
DC20-1892 | TOTAL | 46.87 | 2.59 | |||
DC20-1893 | ACMA | 139.70 | 143.70 | 4.00 | 1.35 | |
DC20-1893 | 223.80 | 230.50 | 6.70 | 1.87 | ||
DC20-1893 | 247.43 | 253.80 | 6.37 | 1.62 | ||
DC20-1893 | TOTAL | 17.07 | 1.65 | |||
DC20-1894 | ACMA | 26.60 | 32.60 | 6.00 | 3.84 | |
DC20-1894 | 132.40 | 136.40 | 4.00 | 3.38 | ||
DC20-1894 | 152.40 | 158.40 | 6.00 | 3.68 | ||
DC20-1894 | 244.20 | 253.80 | 9.60 | 1.00 | ||
DC20-1894 | 259.00 | 263.00 | 4.00 | 9.22 | ||
DC20-1894 | 274.50 | 284.00 | 9.50 | 5.48 | ||
DC20-1894 | 290.00 | 294.00 | 4.00 | 3.83 | ||
DC20-1894 | 345.00 | 348.00 | 3.00 | 4.88 | ||
DC20-1894 | 421.50 | 429.50 | 8.00 | 2.08 | ||
DC20-1894 | 508.00 | 521.63 | 13.63 | 4.45 | ||
DC20-1894 | 558.93 | 580.27 | 21.34 | 3.65 | ||
DC20-1894 | 586.06 | 605.33 | 19.27 | 2.31 | ||
DC20-1894 | TOTAL | 108.34 | 3.57 | |||
DC20-1895 | ACMA | 20.43 | 26.40 | 5.97 | 4.13 | |
DC20-1895 | 218.28 | 242.08 | 23.80 | 6.54 | ||
including | 220.28 | 227.40 | 7.12 | 12.71 | ||
DC20-1895 | 257.63 | 267.00 | 9.37 | 1.62 | ||
DC20-1895 | 286.85 | 289.93 | 3.08 | 3.66 | ||
DC20-1895 | TOTAL | 42.22 | 4.90 | |||
DC20-1897 | ACMA | 17.74 | 28.95 | 11.21 | 2.20 | |
DC20-1897 | 145.10 | 153.04 | 7.94 | 1.62 | ||
DC20-1897 | 219.04 | 225.04 | 6.00 | 2.69 | ||
DC20-1897 | 243.58 | 258.12 | 14.54 | 4.79 | ||
DC20-1897 | 287.70 | 295.70 | 8.00 | 2.62 | ||
DC20-1897 | 321.98 | 325.97 | 3.99 | 8.81 | ||
DC20-1897 | TOTAL | 51.68 | 3.47 | |||
DC20-1898 | ACMA | 222.04 | 231.93 | 9.89 | 4.11 | |
DC20-1898 | TOTAL | 9.89 | 4.11 | |||
DC20-1899 | ACMA | 72.73 | 88.87 | 16.14 | 7.78 | |
including | 72.73 | 76.70 | 3.97 | 13.91 | ||
DC20-1899 | TOTAL | 16.14 | 7.78 | |||
DC20-1900 | Lewis | 90.12 | 94.00 | 3.88 | 2.83 | |
DC20-1900 | 107.20 | 119.30 | 12.10 | 2.37 | ||
DC20-1900 | 140.20 | 150.00 | 9.80 | 4.78 | ||
DC20-1900 | 164.00 | 184.00 | 20.00 | 2.74 | ||
DC20-1900 | 199.00 | 209.00 | 10.00 | 5.61 | ||
DC20-1900 | TOTAL | 55.78 | 3.54 | |||
DC20-1901 | Lewis | 73.66 | 85.15 | 11.49 | 1.16 | |
DC20-1901 | 218.78 | 222.46 | 3.68 | 3.65 | ||
DC20-1901 | 233.97 | 237.50 | 3.53 | 3.43 | ||
DC20-1901 | 302.16 | 306.16 | 4.00 | 3.50 | ||
DC20-1901 | 358.00 | 390.00 | 32.00 | 2.40 | ||
DC20-1901 | TOTAL | 54.70 | 2.37 | |||
DC20-1902 | Lewis | 18.00 | 33.30 | 15.30 | 1.23 | |
DC20-1902 | 96.00 | 103.54 | 7.54 | 4.65 | ||
DC20-1902 | 153.00 | 159.27 | 6.27 | 1.79 | ||
DC20-1902 | TOTAL | 29.11 | 2.24 | |||
DC20-1903 | ACMA | 99.39 | 107.53 | 8.14 | 45.26 | |
including | 99.39 | 106.23 | 6.84 | 52.14 | ||
DC20-1903 | 112.79 | 119.76 | 6.97 | 2.57 | ||
DC20-1903 | TOTAL | 15.11 | 25.57 | |||
DC20-1904 | ACMA | 61.77 | 97.65 | 35.88 | 3.71 | |
DC20-1904 | 103.54 | 109.42 | 5.88 | 4.94 | ||
DC20-1904 | TOTAL | 41.76 | 3.88 | |||
DC20-1905 | Lewis | 41.65 | 45.05 | 3.40 | 4.50 | |
DC20-1905 | 51.00 | 67.00 | 16.00 | 2.45 | ||
DC20-1905 | 81.00 | 89.00 | 8.00 | 1.39 | ||
DC20-1905 | TOTAL | 27.40 | 2.40 | |||
DC20-1906 | ACMA | 225.73 | 237.98 | 12.25 | 6.27 | |
DC20-1906 | TOTAL | 12.25 | 6.27 | |||
DC20-1907 | Lewis | 248.54 | 254.46 | 5.92 | 1.48 | |
DC20-1907 | 367.08 | 385.96 | 18.88 | 5.60 | ||
including | 368.95 | 372.75 | 3.80 | 16.09 | ||
DC20-1907 | 395.45 | 403.24 | 7.79 | 1.64 | ||
DC20-1907 | 418.58 | 428.45 | 9.87 | 3.27 | ||
DC20-1907 | TOTAL | 42.46 | 3.76 | |||
DC20-1908 | Lewis | 112.25 | 122.25 | 10.00 | 2.40 | |
DC20-1908 | TOTAL | 10.00 | 2.40 | |||
DC20-1909 | ACMA | 74.22 | 79.40 | 5.18 | 8.04 | |
DC20-1909 | 94.50 | 98.40 | 3.90 | 3.17 | ||
DC20-1909 | 135.50 | 145.60 | 10.10 | 2.31 | ||
DC20-1909 | TOTAL | 19.18 | 4.03 | |||
DC20-1910 | Lewis | 162.43 | 166.43 | 4.00 | 6.54 | |
DC20-1910 | 184.23 | 193.23 | 9.00 | 7.88 | ||
DC20-1910 | 201.23 | 209.23 | 8.00 | 7.28 | ||
DC20-1910 | TOTAL | 21.00 | 7.40 | |||
DC20-1911 | ACMA | 61.00 | 83.00 | 22.00 | 2.29 | |
DC20-1911 | 105.00 | 113.00 | 8.00 | 2.68 | ||
DC20-1911 | TOTAL | 30.00 | 2.40 | |||
DC20-1912 | Lewis | 178.80 | 198.80 | 20.00 | 4.11 | |
DC20-1912 | 249.70 | 287.00 | 37.30 | 7.00 | ||
including | 251.70 | 255.00 | 3.30 | 24.55 | ||
DC20-1912 | TOTAL | 57.30 | 5.99 | |||
DC20-1913 | Lewis | 15.00 | 19.00 | 4.00 | 4.87 | |
DC20-1913 | 118.53 | 142.00 | 23.47 | 1.87 | ||
DC20-1913 | TOTAL | 27.47 | 2.31 | |||
DC20-1914 | ACMA | 18.44 | 28.44 | 10.00 | 1.92 | |
DC20-1914 | 91.13 | 104.02 | 12.89 | 1.31 | ||
DC20-1914 | 112.88 | 116.88 | 4.00 | 1.05 | ||
DC20-1914 | TOTAL | 26.89 | 1.49 | |||
DC20-1915 | Lewis | 31.90 | 37.55 | 5.65 | 1.08 | |
DC20-1915 | 228.10 | 234.10 | 6.00 | 1.78 | ||
DC20-1915 | 287.42 | 302.78 | 15.36 | 7.22 | ||
including | 298.78 | 302.78 | 4.00 | 21.03 | ||
DC20-1915 | 316.76 | 324.76 | 8.00 | 2.16 | ||
DC20-1915 | TOTAL | 35.01 | 4.14 | |||
DC20-1916 | Lewis | 19.94 | 31.88 | 11.94 | 4.87 | |
DC20-1916 | 49.90 | 58.86 | 8.96 | 5.32 | ||
DC20-1916 | 136.18 | 148.16 | 11.98 | 1.32 | ||
DC20-1916 | 201.59 | 211.58 | 9.99 | 1.57 | ||
DC20-1916 | TOTAL | 42.87 | 3.20 | |||
DC20-1917 | ACMA | 145.56 | 155.35 | 9.79 | 1.41 | |
DC20-1917 | TOTAL | 9.79 | 1.41 | |||
DC20-1920 | Lewis | 6.03 | 10.67 | 4.64 | 4.10 | |
DC20-1920 | TOTAL | 4.64 | 4.10 | |||
DC20-1921 | ACMA | 98.86 | 103.98 | 5.12 | 2.11 | |
DC20-1921 | 109.98 | 116.97 | 6.99 | 5.48 | ||
DC20-1921 | 133.56 | 142.67 | 9.11 | 1.69 | ||
DC20-1921 | 165.67 | 189.40 | 23.73 | 2.64 | ||
DC20-1921 | 206.23 | 209.74 | 3.51 | 5.18 | ||
DC20-1921 | 284.64 | 292.98 | 8.34 | 4.99 | ||
DC20-1921 | 297.12 | 311.16 | 14.04 | 3.27 | ||
DC20-1921 | TOTAL | 70.84 | 3.29 | |||
DC20-1923 | Lewis | 85.60 | 91.55 | 5.95 | 1.68 | |
DC20-1923 | 128.00 | 131.62 | 3.62 | 3.79 | ||
DC20-1923 | TOTAL | 9.57 | 2.48 | |||
DC20-1926 | Lewis | 21.96 | 35.96 | 14.00 | 4.36 | |
DC20-1926 | TOTAL | 14.00 | 4.36 | |||
DC20-1930 | ACMA | 102.30 | 110.30 | 8.00 | 2.62 | |
DC20-1930 | 119.50 | 137.50 | 18.00 | 3.14 | ||
DC20-1930 | 148.85 | 188.00 | 39.15 | 4.28 | ||
including | 182.40 | 188.00 | 5.60 | 12.51 | ||
DC20-1930 | TOTAL | 65.15 | 3.76 | |||
DC20-1937 | ACMA | 335.36 | 341.36 | 6.00 | 6.79 | |
DC20-1937 | 349.30 | 365.63 | 16.33 | 3.20 | ||
DC20-1937 | 390.19 | 494.07 | 103.88 | 6.14 | ||
including | 459.17 | 481.32 | 22.15 | 12.55 | ||
DC20-1937 | 500.10 | 526.63 | 26.53 | 2.40 | ||
DC20-1937 | TOTAL | 152.74 | 5.20 | |||
DC20-1944 | ACMA | 205.38 | 209.00 | 3.62 | 5.45 | |
DC20-1944 | 227.00 | 232.00 | 5.00 | 1.55 | ||
DC20-1944 | 237.62 | 249.22 | 11.60 | 3.59 | ||
DC20-1944 | 274.00 | 277.55 | 3.55 | 8.49 | ||
DC20-1944 | 286.17 | 294.00 | 7.83 | 6.12 | ||
DC20-1944 | TOTAL | 31.60 | 4.66 | |||
DC20-1947 | ACMA | 73.81 | 80.10 | 6.29 | 3.20 | |
DC20-1947 | TOTAL | 6.29 | 3.20 | |||
DC20-1949 | ACMA | 28.84 | 32.56 | 3.72 | 2.28 | |
DC20-1949 | 64.93 | 70.44 | 5.51 | 3.30 | ||
DC20-1949 | 96.01 | 100.58 | 4.57 | 2.17 | ||
DC20-1949 | 141.35 | 156.70 | 15.35 | 5.37 | ||
DC20-1949 | TOTAL | 29.15 | 4.08 | |||
DC20-1950 | ACMA | 161.50 | 175.50 | 14.00 | 2.63 | |
DC20-1950 | 180.80 | 193.05 | 12.25 | 3.14 | ||
DC20-1950 | 230.30 | 237.50 | 7.20 | 5.91 | ||
DC20-1950 | 250.00 | 262.50 | 12.50 | 3.49 | ||
DC20-1950 | 272.00 | 277.38 | 5.38 | 2.24 | ||
DC20-1950 | 295.15 | 302.00 | 6.85 | 5.17 | ||
DC20-1950 | 307.00 | 314.50 | 7.50 | 4.84 | ||
DC20-1950 | TOTAL | 65.68 | 3.73 | |||
DC20-1951 | ACMA | 109.96 | 123.88 | 13.92 | 2.34 | |
DC20-1951 | TOTAL | 13.92 | 2.34 |
Significant intervals represent drilled intervals and not necessarily true thickness of mineralization. Mineralized intervals meet or exceed 3 meters in length above 1 g/t. A maximum of 4 meters of continuous dilution (< 1 g/t) is permitted. Any drill intervals not depicted in this table did not meet the significant interval criteria.
Assay data are not yet available from 118.26m to 214.64m in DC20-1895, from 159.90m to 239.27m in DC20-1909, from 0.00m to 46.00m in DC20-1912, from 142.00m to 224.94m in DC20-1913, from 0.00m to 39.70m and 155.35m to 175.26m in DC20-1917, all of DC20-1918 and DC20-1919, from 131.30m to 253.29m in DC20-1920, from 0.00m to 93.26m and 311.16m to 607.16m in DC20-1921, from 56.25m to 254.51m in DC20-1922, from 0.00m to 69.28m and 190.30m to 211.53m in DC20-1923, all of DC20-1924 and DC20-1925, from 0.00m to 104.00m in DC20-1927, from 58.03m to 226.16m in DC20-1928, all of DC20-1929, from 0.00m to 64.00m and 188.00m to 233.17m in DC20-1930, all of DC20-1932 through DC20-1936, from 0.00m to 329.42m in DC20-1937, all of DC20-1938, from 58.04m to 151.79m in DC20-1939, all of DC20-1940 through DC20-1943, from 0.00m to 154.87m in DC20-1944, all of DC20-1945 and DC20-1946, from 91.90m to 240.18m in DC20-1947, all of DC20-1948, from 187.00m to 303.58m in DC20-1949, from 0.00m to 83.40m and 314.50m to 334.06m in DC20-1950, and from 0.00m to 33.16m and 123.88m to 178.77m in DC20-1951.
______________________
1 Donlin Gold data as per the Second Updated Feasibility Study (as defined below). Donlin Gold measured resources of approximately 8 Mt grading 2.52 g/t and indicated resources of approximately
Figure 1 Drill Hole Collar Locations
![](https://ml.globenewswire.com/media/29faa507-44a1-4ead-bf57-0d534d493951/medium/figure-1-drill-hole-collar-locations.jpg)
Depicted grid system is based on NAD83 UTM zone 4N coordinates.
2021 GlobeNewswire, Inc., source