Dr.
Cantex is pleased to report results from a further five drill holes from its 2022 drill program at the
The results from the five holes are presented in Table 1. Figure 1 shows the locations of the drill pads discussed in this release.
Hole YKDD22-246 was drilled from pad MZ52, a 50 metre step out from the previous year's drilling, and intersected 23.5 metres of 20.46 g/t silver and 8.34% combined lead and zinc. Within this intercept there were two higher grade zones, both 2.5 metres long. The first contained 44.68 g/t silver ad 19.06% combined lead and zinc. The second contained 85.32 g/t silver and 24.72% combined lead and zinc. A cross section of these holes is shown in Figure 2.
Holes YKDD22-250, YKDD22-255 and YKDD22-257 were drilled from pad MZ53A, a 100 metre step out from the drilling in 2021. Figure 3 shows a cross section through these holes.
Hole YKDD22-254 was drilled from pad MZ54A, a 150 metre step out from the drilling in 2021. It intersected several zones of mineralization including a 12.7 metre zone within which 1.5 metres contained 75.33 g/t silver and 24.21% combined lead and zinc. A cross section through these holes is presented in Figure 4.
Table 1. Significant results from Discovery Sector
Pad | Dip | Hole | From | To | Interval | Silver | Lead | Zinc | Lead + | Cop- | Manga- |
(m) | (m) | (m) | ppm | ( %) | ( %) | ( %) | ( %) | ( %) | |||
MZ52 | -65 | YKDD22-246 | 49.00 | 52.00 | 3.00 | 4.07 | 0.68 | 1.52 | 2.20 | 0.00 | 0.31 |
55.00 | 78.50 | 23.50 | 20.46 | 3.30 | 5.04 | 8.34 | 0.01 | 4.53 | |||
Including | 57.50 | 60.00 | 2.50 | 44.68 | 3.39 | 15.67 | 19.06 | 0.03 | 4.62 | ||
And | 73.50 | 76.00 | 2.50 | 85.32 | 13.79 | 10.93 | 24.72 | 0.04 | 3.66 | ||
90.00 | 91.00 | 1.00 | 7.19 | 1.88 | 0.53 | 2.41 | 0.01 | 0.98 | |||
MZ53A | -55 | YKDD22-250 | 25.00 | 25.50 | 0.50 | 15.35 | 0.32 | 3.87 | 4.19 | 0.04 | 0.13 |
156.00 | 166.00 | 10.00 | 38.60 | 6.39 | 7.60 | 13.99 | 0.06 | 2.86 | |||
180.00 | 183.50 | 3.50 | 52.76 | 7.97 | 4.62 | 12.59 | 0.13 | 2.22 | |||
194.35 | 195.20 | 0.85 | 19.65 | 4.26 | 2.84 | 7.10 | 0.08 | 0.47 | |||
207.15 | 207.65 | 0.50 | 15.50 | 2.68 | 3.75 | 6.43 | 0.02 | 3.01 | |||
210.50 | 211.10 | 0.60 | 4.60 | 0.55 | 1.46 | 2.01 | 0.01 | 1.22 | |||
-71 | YKDD22-255 | 201.00 | 212.00 | 11.00 | 11.91 | 0.56 | 2.86 | 3.42 | 0.07 | 1.48 | |
Including | 201.00 | 204.00 | 3.00 | 36.27 | 1.45 | 5.38 | 6.83 | 0.22 | 1.70 | ||
278.70 | 281.50 | 2.80 | 4.59 | 0.69 | 1.97 | 2.66 | 0.01 | 1.28 | |||
-75 | YKDD22-257 | 220.20 | 223.00 | 2.80 | 62.66 | 7.06 | 3.45 | 10.51 | 0.18 | 1.25 | |
246.10 | 247.60 | 1.50 | 1.95 | 0.06 | 1.08 | 1.14 | 0.01 | 0.95 | |||
MZ54A | -55 | YKDD22-254 | 150.30 | 163.00 | 12.70 | 24.25 | 1.04 | 3.20 | 4.24 | 0.08 | 2.63 |
Including | 150.30 | 151.80 | 1.50 | 75.33 | 4.59 | 19.62 | 24.21 | 0.06 | 2.71 | ||
169.00 | 169.50 | 0.50 | 14.00 | 3.22 | 6.23 | 9.45 | 0.01 | 4.08 | |||
173.00 | 173.50 | 0.50 | 25.90 | 1.48 | 8.07 | 9.55 | 0.03 | 3.66 | |||
178.50 | 182.50 | 4.00 | 34.21 | 6.47 | 5.12 | 11.59 | 0.12 | 3.06 | |||
Including | 179.00 | 180.50 | 1.50 | 69.60 | 13.96 | 9.97 | 23.93 | 0.16 | 3.29 | ||
220.00 | 221.00 | 1.00 | 5.49 | 0.58 | 3.55 | 4.13 | 0.00 | 1.02 |
During 2022 the Company drilled 13,187 metres in 62 holes. Results are awaited from 46 holes and will be released when received.
The drill holes reported in this press release were drilled using HQ (63.5mm) diamond drill bits. The core was logged, marked up for sampling and then divided into equal halves using a diamond saw on site. One half of the core was left in the original core box. The other half was sampled and placed into sealed bags which were in turn placed into larger bags closed with security seals prior to being transported to
At CF Minerals the drill core was dried prior to crushing to -10 mesh. The samples, which averaged over 3kg, were then mixed prior to splitting off 800g. The 800g splits were pulverized to -200 mesh and a 250g split was sent for assay. Quality control procedures included running a barren sand sample through both the crusher and pulveriser between each sample to ensure no inter-sample contamination occurred. Silica blanks were inserted along with certified reference samples. These quality control samples were each inserted approximately every 20 samples.
The technical information and results reported here have been reviewed by Mr.
Signed,
Chairman
Neither
SOURCE
© Canada Newswire, source